View All Configured Switched UNI I-SIDs

Perform this procedure to view all the configured Switched UNI I-SIDs including their types, ports, and MLTs.

Procedure

  1. Enter Privileged EXEC mode:

    enable

  2. View all configured CVLAN, T-UNI, and S-UNI based I-SIDs:

    show i-sid

  3. View all S-UNI I-SIDs.

    show i-sid [elan]

  4. View all associated MLT on the S-UNI I-SID.

    show mlt i-sid [MLT ID <1–512>]

  5. View all associated ports on the S-UNI I-SID.

    show interfaces gigabitethernet i-sid {sub-port]][,...][slot/all][all]}

  6. View all IS-IS SPBM multicast FIB entries.

    show isis spbm multicast-fib detail

Examples

View all configured I-SIDs.

Switch:1#show i-sid
===========================================================================================================
                                                       Isid Info
===========================================================================================================
ISID       ISID                   PORT             MLT           ORIGIN                    ISID
ID         TYPE      VLANID       INTERFACES       INTERFACES                              NAME 
-----------------------------------------------------------------------------------------------------------
15999999   ELAN     4048          -                -             C  ---  -  ---  -  -      Onboarding I-SID
16777001   ELAN     N/A           -                -             C  ---  -  ---  -  -      FAN-ISID

c: customer vid    u: untagged-traffic

All 2 out of 2 Total Num of i-sids displayed

ORIGIN Legend:
C: manually configured; D: discovered by FA or EPT
M: FA management; E: discovered by EAP; A: auto-sense; R: multi-area redist
l: discover by local switch  r: discover by remote VIST switch

View all S-UNI I-SIDs.

Switch:1>show i-sid elan

==============================================================================================
                                    Isid Info
==============================================================================================
ISID      ISID              PORT               MLT         ORIGIN                    ISID
ID        TYPE     VLANID   INTERFACES         INTERFACES                            NAME
----------------------------------------------------------------------------------------------
27        ELAN     N/A      c4000:1/1,2/1      -           C  ---  -  ---  -         ISID-27
38        ELAN     N/A      c4000:1/2,2/2      -           C  ---  -  ---  -         ISID-38
270       ELAN     N/A      c4001:1/1,2/1      -           C  ---  -  ---  -         ISID-270
307       ELAN     N/A      c307:1/5,2/1       -           C  ---  -  ---  -         ISID-307
308       ELAN     N/A      c308:1/6,2/1       -           C  ---  -  ---  -         ISID-308
309       ELAN     N/A      c309:1/1,2/1       -           C  ---  -  ---  -         ISID-309
310       ELAN     N/A      c310:1/2,2/2       -           C  ---  -  ---  -         ISID-310
311       ELAN     N/A      c311:1/3,2/2       -           C  ---  -  ---  -         ISID-311
312       ELAN     N/A      c312:1/4,2/2       -           C  ---  -  ---  -         ISID-312
317       ELAN     N/A      c317:1/7,2/1       -           C  ---  -  ---  -         ISID-317
318       ELAN     N/A      c318:1/8,2/1       -           C  ---  -  ---  -         ISID-318
319       ELAN     N/A      c319:1/9,2/1       -           C  ---  -  ---  -         ISID-319
320       ELAN     N/A      c320:1/10,2/1      -           C  ---  -  ---  -         ISID-320

--More-- (q = quit)

c: customer vid    u: untagged-traffic

13 out of 77 Total Num of Elan displayed

ORIGIN Legend:
C: manually configured; D: discovered by FA or EPT
M: FA management; E: discovered by EAP; A: auto-sense
l: discover by local switch  r: discover by remote VIST switch

View all associated MLT on the S-UNI I-SID.

Switch:1>show mlt i-sid
=====================================================================================
                                  MLT Isid Info
=====================================================================================
                  ISID                     ISID                         ISID
MLTID   IFINDEX   ID     VLANID   C-VID    TYPE      ORIGIN             NAME      BPDU
-------------------------------------------------------------------------------------
3       6146      3      N/A      33       ELAN      C  ---  -  ---  -  ISID-3
-------------------------------------------------------------------------------------
1 out of 1 Total Num of i-sid endpoints displayed

ORIGIN Legend:
C: manually configured; D: discovered by FA or EPT
M: FA management; E: discovered by EAP; A: auto-sense
l: discover by local switch  r: discover by remote VIST switch

View all associated ports on the S-UNI I-SID.

Switch:1#show interfaces gigabitEthernet i-sid
=======================================================================================
                           PORT Isid Info
=======================================================================================
                ISID                   ISID                        ISID              MAC
PORTNUM IFINDEX ID       VLANID C-VID  TYPE     ORIGIN             NAME        BPDU  SUNI
----------------------------------------------------------------------------------------
1/1     192     27       N/A    4000   ELAN     C  ---  -  ---  -  ISID-27           FALSE
1/1     192     270      N/A    4001   ELAN     C  ---  -  ---  -  ISID-270          FALSE
1/1     192     309      N/A    309    ELAN     C  ---  -  ---  -  ISID-309          FALSE
1/1     192     401      N/A    401    ELAN     C  ---  -  ---  -  ISID-401          FALSE
1/1     192     1001     N/A    1001   ELAN     C  ---  -  ---  -  ISID-1001         FALSE
1/1     192     1111     N/A    1111   ELAN     C  ---  -  ---  -  ISID-1111         FALSE
1/1     192     1121     N/A    1121   ELAN     C  ---  -  ---  -  ISID-1121         FALSE
1/1     192     1201     N/A    1201   ELAN     C  ---  -  ---  -  ISID-1201         FALSE
1/1     192     2001     N/A    2001   ELAN     C  ---  -  ---  -  ISID-2001         FALSE
1/2     193     38       N/A    4000   ELAN     C  ---  -  ---  -  ISID-38           FALSE
1/2     193     310      N/A    310    ELAN     C  ---  -  ---  -  ISID-310          FALSE
1/2     193     380      N/A    4001   ELAN     C  ---  -  ---  -  ISID-380          FALSE
1/2     193     402      N/A    402    ELAN     C  ---  -  ---  -  ISID-402          FALSE

13 out of 152 Total Num of i-sid endpoints displayed

ORIGIN Legend:
C: manually configured; D: discovered by FA or EPT
M: FA management; E: discovered by EAP; A: auto-sense
l: discover by local switch  r: discover by remote VIST switch

View all IS-IS SPBM multicast FIB entries.

Switch:1#show isis spbm multicast-fib detail
=====================================================================================================================================
                           SPBM MULTICAST FIB ENTRY DETAIL INFO
=====================================================================================================================================
MCAST DA           ISID      BVLAN SYSID           HOST-NAME         OUTGOING-INTERFACES    INCOMING    CVLAN AREA       AREA-NAME
                                                                                            INTERFACE
--------------------------------------------------------------------------------------------------------------------------------------
03:00:20:00:00:65  101       4051  0200.20ff.fff0  vn-area-20.0020    1/32                   Virtual    101   HOME       area-10.0010
03:00:20:00:00:67  103       4051  0200.20ff.fff0  vn-area-20.0020    1/32                   Virtual    103   HOME       area-10.0010
03:00:20:00:00:69  105       4051  0200.20ff.fff0  vn-area-20.0020    1/32                   Virtual    105   HOME       area-10.0010
03:00:20:00:00:6b  107       4051  0200.20ff.fff0  vn-area-20.0020    1/32                   Virtual    107   HOME       area-10.0010
03:00:20:00:00:6d  109       4051  0200.20ff.fff0  vn-area-20.0020    1/32                   Virtual    109   HOME       area-10.0010
03:00:20:00:00:6f  111       4051  0200.20ff.fff0  vn-area-20.0020    1/32                   Virtual    111   HOME       area-10.0010
03:00:20:00:00:71  113       4051  0200.20ff.fff0  vn-area-20.0020    1/32                   Virtual    113   HOME       area-10.0010
03:00:20:00:00:73  115       4051  0200.20ff.fff0  vn-area-20.0020    1/32                   Virtual    115   HOME       area-10.0010
03:00:20:00:00:75  117       4051  0200.20ff.fff0  vn-area-20.0020    1/32                   Virtual    117   HOME       area-10.0010
03:00:20:00:00:77  119       4051  0200.20ff.fff0  vn-area-20.0020    1/32                   Virtual    119   HOME       area-10.0010
03:00:20:00:00:79  121       4051  0200.20ff.fff0  vn-area-20.0020    1/32                   Virtual    121   HOME       area-10.0010
03:00:20:00:00:7b  123       4051  0200.20ff.fff0  vn-area-20.0020    1/32                   Virtual    123   HOME       area-10.0010
13:00:11:00:00:65  101       4051  a425.1b53.7084  BEB1-7200          1/32                   MLT-2      101   HOME       area-10.0010


---------------------------------------------------------------------------------------------------------------------------------------
13 out of 2354 Total Num of SPBM MULTICAST FIB entries displayed
Remote: 0 out of 0 Total Num of SPBM MULTICAST FIB entries displayed
---------------------------------------------------------------------------------------------------------------------------------------

Variable Definitions

The following table defines parameters for the i-sid command.

Variable

Value

elan

Displays only all the ELAN (S-UNI based) I-SIDs.

MLT ID <1–512>

Specifies the MLT associated with the Switched UNI I-SID.

{sub-port]][,...][slot/all][all]}

Specifies the ports associated with the Switched UNI I-SID.