View All Configured Switched UNI I-SIDs
Perform this procedure to view all the configured Switched UNI I-SIDs including their types, ports, and MLTs.
Procedure
Examples
View all configured I-SIDs.
Switch:1#show i-sid
===========================================================================================================
Isid Info
===========================================================================================================
ISID ISID PORT MLT ORIGIN ISID
ID TYPE VLANID INTERFACES INTERFACES NAME
-----------------------------------------------------------------------------------------------------------
15999999 ELAN 4048 - - C --- - --- - - Onboarding I-SID
16777001 ELAN N/A - - C --- - --- - - FAN-ISID
c: customer vid u: untagged-traffic
All 2 out of 2 Total Num of i-sids displayed
ORIGIN Legend:
C: manually configured; D: discovered by FA or EPT
M: FA management; E: discovered by EAP; A: auto-sense; R: multi-area redist
l: discover by local switch r: discover by remote VIST switch
View all S-UNI I-SIDs.
Switch:1>show i-sid elan
==============================================================================================
Isid Info
==============================================================================================
ISID ISID PORT MLT ORIGIN ISID
ID TYPE VLANID INTERFACES INTERFACES NAME
----------------------------------------------------------------------------------------------
27 ELAN N/A c4000:1/1,2/1 - C --- - --- - ISID-27
38 ELAN N/A c4000:1/2,2/2 - C --- - --- - ISID-38
270 ELAN N/A c4001:1/1,2/1 - C --- - --- - ISID-270
307 ELAN N/A c307:1/5,2/1 - C --- - --- - ISID-307
308 ELAN N/A c308:1/6,2/1 - C --- - --- - ISID-308
309 ELAN N/A c309:1/1,2/1 - C --- - --- - ISID-309
310 ELAN N/A c310:1/2,2/2 - C --- - --- - ISID-310
311 ELAN N/A c311:1/3,2/2 - C --- - --- - ISID-311
312 ELAN N/A c312:1/4,2/2 - C --- - --- - ISID-312
317 ELAN N/A c317:1/7,2/1 - C --- - --- - ISID-317
318 ELAN N/A c318:1/8,2/1 - C --- - --- - ISID-318
319 ELAN N/A c319:1/9,2/1 - C --- - --- - ISID-319
320 ELAN N/A c320:1/10,2/1 - C --- - --- - ISID-320
--More-- (q = quit)
c: customer vid u: untagged-traffic
13 out of 77 Total Num of Elan displayed
ORIGIN Legend:
C: manually configured; D: discovered by FA or EPT
M: FA management; E: discovered by EAP; A: auto-sense
l: discover by local switch r: discover by remote VIST switch
View all associated MLT on the S-UNI I-SID.
Switch:1>show mlt i-sid
=====================================================================================
MLT Isid Info
=====================================================================================
ISID ISID ISID
MLTID IFINDEX ID VLANID C-VID TYPE ORIGIN NAME BPDU
-------------------------------------------------------------------------------------
3 6146 3 N/A 33 ELAN C --- - --- - ISID-3
-------------------------------------------------------------------------------------
1 out of 1 Total Num of i-sid endpoints displayed
ORIGIN Legend:
C: manually configured; D: discovered by FA or EPT
M: FA management; E: discovered by EAP; A: auto-sense
l: discover by local switch r: discover by remote VIST switch
View all associated ports on the S-UNI I-SID.
Switch:1#show interfaces gigabitEthernet i-sid
=======================================================================================
PORT Isid Info
=======================================================================================
ISID ISID ISID MAC
PORTNUM IFINDEX ID VLANID C-VID TYPE ORIGIN NAME BPDU SUNI
----------------------------------------------------------------------------------------
1/1 192 27 N/A 4000 ELAN C --- - --- - ISID-27 FALSE
1/1 192 270 N/A 4001 ELAN C --- - --- - ISID-270 FALSE
1/1 192 309 N/A 309 ELAN C --- - --- - ISID-309 FALSE
1/1 192 401 N/A 401 ELAN C --- - --- - ISID-401 FALSE
1/1 192 1001 N/A 1001 ELAN C --- - --- - ISID-1001 FALSE
1/1 192 1111 N/A 1111 ELAN C --- - --- - ISID-1111 FALSE
1/1 192 1121 N/A 1121 ELAN C --- - --- - ISID-1121 FALSE
1/1 192 1201 N/A 1201 ELAN C --- - --- - ISID-1201 FALSE
1/1 192 2001 N/A 2001 ELAN C --- - --- - ISID-2001 FALSE
1/2 193 38 N/A 4000 ELAN C --- - --- - ISID-38 FALSE
1/2 193 310 N/A 310 ELAN C --- - --- - ISID-310 FALSE
1/2 193 380 N/A 4001 ELAN C --- - --- - ISID-380 FALSE
1/2 193 402 N/A 402 ELAN C --- - --- - ISID-402 FALSE
13 out of 152 Total Num of i-sid endpoints displayed
ORIGIN Legend:
C: manually configured; D: discovered by FA or EPT
M: FA management; E: discovered by EAP; A: auto-sense
l: discover by local switch r: discover by remote VIST switch
View all IS-IS SPBM multicast FIB entries.
Switch:1#show isis spbm multicast-fib detail
=====================================================================================================================================
SPBM MULTICAST FIB ENTRY DETAIL INFO
=====================================================================================================================================
MCAST DA ISID BVLAN SYSID HOST-NAME OUTGOING-INTERFACES INCOMING CVLAN AREA AREA-NAME
INTERFACE
--------------------------------------------------------------------------------------------------------------------------------------
03:00:20:00:00:65 101 4051 0200.20ff.fff0 vn-area-20.0020 1/32 Virtual 101 HOME area-10.0010
03:00:20:00:00:67 103 4051 0200.20ff.fff0 vn-area-20.0020 1/32 Virtual 103 HOME area-10.0010
03:00:20:00:00:69 105 4051 0200.20ff.fff0 vn-area-20.0020 1/32 Virtual 105 HOME area-10.0010
03:00:20:00:00:6b 107 4051 0200.20ff.fff0 vn-area-20.0020 1/32 Virtual 107 HOME area-10.0010
03:00:20:00:00:6d 109 4051 0200.20ff.fff0 vn-area-20.0020 1/32 Virtual 109 HOME area-10.0010
03:00:20:00:00:6f 111 4051 0200.20ff.fff0 vn-area-20.0020 1/32 Virtual 111 HOME area-10.0010
03:00:20:00:00:71 113 4051 0200.20ff.fff0 vn-area-20.0020 1/32 Virtual 113 HOME area-10.0010
03:00:20:00:00:73 115 4051 0200.20ff.fff0 vn-area-20.0020 1/32 Virtual 115 HOME area-10.0010
03:00:20:00:00:75 117 4051 0200.20ff.fff0 vn-area-20.0020 1/32 Virtual 117 HOME area-10.0010
03:00:20:00:00:77 119 4051 0200.20ff.fff0 vn-area-20.0020 1/32 Virtual 119 HOME area-10.0010
03:00:20:00:00:79 121 4051 0200.20ff.fff0 vn-area-20.0020 1/32 Virtual 121 HOME area-10.0010
03:00:20:00:00:7b 123 4051 0200.20ff.fff0 vn-area-20.0020 1/32 Virtual 123 HOME area-10.0010
13:00:11:00:00:65 101 4051 a425.1b53.7084 BEB1-7200 1/32 MLT-2 101 HOME area-10.0010
---------------------------------------------------------------------------------------------------------------------------------------
13 out of 2354 Total Num of SPBM MULTICAST FIB entries displayed
Remote: 0 out of 0 Total Num of SPBM MULTICAST FIB entries displayed
---------------------------------------------------------------------------------------------------------------------------------------
Variable Definitions
The following table defines parameters for the i-sid command.
|
Variable |
Value |
|---|---|
|
elan |
Displays only all the ELAN (S-UNI based) I-SIDs. |
|
MLT ID <1–512> |
Specifies the MLT associated with the Switched UNI I-SID. |
|
{sub-port]][,...][slot/all][all]} |
Specifies the ports associated with the Switched UNI I-SID. |